| Specifications |
Max. Board Size |
13 x 15.7"(330 x 400mm) |
Number of Probe |
2 Front, 2 Rear |
Min. Board Size |
0.8 x 2"(20 x 50mm) |
Max. Board Thickness for Clamping |
0.354"(9mm) |
Repeatable Accuracy |
±0.000118"(±3µm) |
Resolution |
0.000039"(1µm) |
Min. Pad Pitch |
0.001969"(50µm) |
Min. Pad Size |
0.000787"(20µm) |
Test Voltage of Resistance Measurement |
Continuity test : 0-10V Isolation test : 250V(500V/1000V option) |
Test Current of Resistance Measurement |
Continuity test : 2.65 µA-125mA |
Clamp System |
Pneumatic |
Number of CCD Camera |
2 Front, 2 Rear |
Monitor |
not available |
Printer |
external(option) |
Air Requirements(Pressure, Consumption) |
0.5MPa, 1.5gal/min.(5.7Ltr/min.) |
Power Supply (Single Phase AC200-240V 50/60Hz)†1 |
10A |
Weight |
2800lbs.(1270kg) |
Dimensions |
 |
†1 Power Supply : There is a case incoming current about decuple of amperage rating might pass when power is on. Please choose breaker that will not cause any malfunction by this incoming current.
[System Requirements] Control PC & Monitor
[Software] EMMA2000 is standard, Ask our sales department about our optional software.
[Probe Type] Users can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC.
[Operating Conditions] 70-75°F (21-24°C), 30-70% relative humidity, non-condensing, no dust, no vibration, no corrosive gas.
Please click here to view flyer for EHX4033(PDF:515KB) |
|